Eaton 5P2200 – UPS 1950 VA 1920 W (Tower)
Overview
The Eaton 5P2200 is a line‑interactive single‑phase UPS designed to deliver short‑duration battery backup and voltage conditioning for 120 V IT systems and edge infrastructure. It is deployed by infrastructure engineers and network architects in network closets, branch office racks, and edge locations to protect servers, storage, switches, firewalls, and other sensitive loads from power outages, brownouts, and voltage excursions. The UPS enables orderly shutdowns and maintains service continuity during transient power events. Verified specifications below are drawn from official Eaton documentation and cross‑checked sources.
With a 1950 VA / 1920 W capacity and true sine‑wave output, the 5P2200 conditions incoming mains and transitions to battery when utility voltage is outside configured thresholds. It uses a line‑interactive topology to optimize transfer time and battery use. The UPS integrates ABM battery management to extend battery life and provides a user‑replaceable sealed lead‑acid battery.
This model is supplied in a tower form factor with an 8 ft power cord terminating in a NEMA 5‑20P input suitable for standard 120 V North American electrical ecosystems. Output receptacles provide a mix of NEMA 5‑15R and 5‑20R outlets to match common plug types on server and network equipment.
Communications include USB (HID) and RS‑232 serial interfaces for local management, plus a single expansion slot for an optional gigabit network management card to enable remote monitoring, alerts, and integration with centralized power management platforms such as Eaton Intelligent Power Manager.
Practical deployment example: In a branch office rack or IDF closet with a 24‑port PoE switch, firewall, and small storage server, the 5P2200 can provide conditioned power and runtime sufficient to bridge short outages and maintain connectivity until generator transfer completes or orderly shutdown scripts execute.
Where not to deploy: This UPS should not be used for 208/230 V mains environments without step‑down transformers, high‑density server racks exceeding ~1920 W, or applications requiring extensive runtime beyond the internal battery capacity, as this model does not support external battery extension modules.
Key Features
- Line‑interactive UPS with 1950 VA / 1920 W capacity Mixed NEMA 5‑15R & 5‑20R outlets, NEMA 5‑20P input ABM battery tech with user‑replaceable sealed lead‑acid USB (HID) + RS‑232 comms; optional network card slot Tower form factor for racks and closets


Write a Review