Eaton IS300HGDV Isolator Series 300W Medical Isolation Transformer

Part No:IS300HGDV Write a Review

Condition:New

Brand:Eaton

Weight:12.346 lbs

Product Type:Medical‑Grade Isolation Transformer

Eaton IS300HGDV – Medical‑Grade Isolation Transformer 300 W

Overview

The Eaton IS300HGDV is a compact medical‑grade isolation transformer designed to provide galvanic isolation and line conditioning for sensitive electrical loads. It is typically deployed by infrastructure engineers, medical equipment installers, and facility electrical technicians to protect sensitive electronic devices from mains noise, surges, and leakage currents in clinical and controlled environments.

This unit is rated for 300 VA / 300 W continuous load and operates across dual voltage configurations (115 VAC and 230 VAC, selectable by fuse configuration). It incorporates a toroidal isolation transformer with inherent Faraday shielding, providing 100 % isolation from the input AC mains and reducing leakage current to < 50 µA, meeting applicable safety standards. Continuous EMI/RFI line noise filtering and 240 joule surge suppression are integrated for power quality improvement.

IS300HGDV is physically sized for placement at point‑of‑use distribution — such as in equipment racks, telecom closets, diagnostic labs, or medical equipment zones — where mains power integrity is required without consuming a full UPS footprint. Its rugged metal enclosure supports standard utility power workflows but does not include rack‑mount hardware by default.

Compatibility includes IEC 60601‑1 medical safety standards required for patient‑care vicinity use, and the unit integrates with industry‑standard power cord infrastructure (requires a C14 inlet cord with local mains plug, sold separately). The transformer’s output remains floating relative to earth ground to reduce ground loop risks.

In practice, this transformer is deployed at the power entry for network switches, clinical instruments, AV boards, or sensitive test gear where noise and leakage performance matter. It is not suitable for high‑power loads (>300 W), continuous industrial motor loads, or installations requiring built‑in surge staging with high joule ratings beyond 240 J.

Avoid using this unit as a substitute for full uninterruptible power systems in critical uptime environments; it does not provide battery backup during utility failures. It also is not intended for use outdoors or in high‑humidity unconditioned spaces.

Key Features

  • Dual selectable 115/230 VAC input/output configuration
  • 300 VA / 300 W continuous isolation transformer capacity
  • Four IEC C13 output receptacles with overload fuse protection
  • Less than 50 µA cumulative leakage current per IEC 60601‑1
  • 240 J surge suppression with EMI/RFI filtering
BrandEaton
SKUIS300HGDV
ConditionNew
Dimensions7.874 × 5.906 × 4.331 in
Weight12.346 lbs
Part NumberIS300HGDV
Product TypeMedical‑Grade Isolation Transformer
Power Capacity300 VA / 300 W
Nominal Input Voltage115/230 VAC (Selectable)
Operating Voltage Range100–125 VAC or 200–250 VAC (via fuse config)
Nominal Frequency50/60 Hz
Input ConnectorIEC‑320‑C14
Output Connectors4 × IEC C13
Output Voltage Regulation±5.2 % (line mode)
Surge Suppression240 J
Transformer TypeToroidal isolation with Faraday shield
Operating Temp.0 °C to 40 °C
Storage Temp.–15 °C to 50 °C
Humidity (Operating)5 % to 95 % RH (non‑condensing)
CertificationsIEC 60601‑1; CAN/CSA‑C22.2 No. 60601‑1; CE; NOM

Warranty

Products include the manufacturer warranty where applicable. Warranty coverage, term, and service options may vary by manufacturer and product condition.

Returns

We guarantee free replacements on all new/refurbished equipment in case of any defects.

  • Returns must be requested within 30 days of the original invoice date.
  • Merchandise must be unused and in original packaging; bulk-packed and refurbished items must have unbroken sealing tape.
  • A 25% restocking fee applies to non-defective merchandise returned by mistake.
  • Discontinued, close-out, and custom printed items are non-returnable unless defective.
  • Customer is responsible for return freight costs.

View full return policy

Customer Reviews of the Eaton IS300HGDV Isolator Series 300W Medical Isolation Transformer

Based on 0 Reviews
5 Stars
0% (0)
4 Stars
0% (0)
3 Stars
0% (0)
2 Stars
0% (0)
1 Star
0% (0)

Filter Results

Do you own this product?

Write a Review

There are no reviews yet.

Write a Review

Your email address will not be published. Required fields are marked *

We Accept

  • PayPal
  • All Credit & Debit Cards
  • Purchase Orders
  • Check
  • Bank Transfer / ACH / Wire Transfer

To pay by PayPal or credit/debit card, simply check out and process payment online.

To pay by Purchase Order, Check, or Bank Transfer, please contact us:
Call: (469) 458-9636
Email: sales@dcsupplies.net

All packages are shipped same day if the order is placed before 3PM CST.

We use UPS/FedEx to ship packages, with different service levels offered by UPS/FedEx:

  • Overnight Shipping - 1 business day
  • Expedited Shipping - about 2-3 business days
  • Ground Shipping - about 3-5 business days

You can select the desired service level at checkout, and we will make sure the package is shipped per the selected service level.