Eaton PDUH20DV Tripp Lite Single Phase 100 240V Basic PDU Rack Mount

Part No:PDUH20DV Write a Review

Condition:New

Brand:Eaton

Weight:5.5 lbs

Product Type:Basic Rack Power Distribution Unit (PDU)

Eaton PDUH20DV 1U 100‑240V 20A 14‑Outlet Basic PDU

Overview :

The Eaton PDUH20DV is a 1U basic power distribution unit (PDU) engineered to distribute single‑phase AC power to rack‑mounted IT loads. Rack and data center engineers deploy this model in wiring closets, server rooms, and edge racks to provide reliable outlet density for switches, servers, storage and peripheral equipment from a UPS, generator or facility feed.

Rated for 100–240 V AC operation and continuous up to 20 A service, it supplies 14 outlets (12 IEC‑320 C13 + 2 IEC‑320 C19). The unit’s all‑metal housing and reversible mounting ears support installation in EIA‑310‑standard 19″ racks, under‑counter positions, or mounted on walls and workbenches.

This PDU fits basic power distribution points where monitoring or switching functions are not required. It is commonly placed at the rear of network and server racks, in IDFs (Intermediate Distribution Frames) and branch‑office cabinets to centralize AC receptacles.

Integration uses a C20 inlet with included 12 ft (3.66 m) detachable cord, and an included NEMA L6‑20P adapter for 208/240 V sources. There is no on/off switch to prevent accidental equipment shutdowns.

In practice, the PDUH20DV serves deployments with solid grounding and UPS backup where outlet count and basic distribution are primary requirements. It is not designed for switched control, metering, network management, or three‑phase feeds — specify switched or metered PDUs for those capabilities.

Key Features

  • 14 outlets: 12 IEC‑320 C13 + 2 IEC‑320 C19

  • Single‑phase 100–240 V AC, 20 A distribution

  • C20 inlet with detachable cord + NEMA L6‑20P adapter

  • Reversible all‑metal housing for rack/under‑counter/wall

  • Switchless design to avoid accidental power interruption

BrandEaton
SKUPDUH20DV
ConditionNew
Dimensions20.1 × 10.9 × 2.25 in
Weight5.5 lbs
Part NumberPDUH20DV
Product TypeBasic Rack Power Distribution Unit (PDU)
Rated Input Voltage100–240 V AC
Rated Current20 A (16 A continuous agency‑de‑rated)
Power Capacity1.6–3.8 kW (dependent on input voltage)
Input ConnectorIEC 60320 C20 inlet with L6‑20P adapter
Output Connectors12 × IEC‑320 C13, 2 × IEC‑320 C19
Frequency50/60 Hz
Form Factor1U horizontal rackmount (also 0U vertical)
HousingAll‑metal, reversible
Mounting OptionsRack, wall, under‑counter
GroundingRear panel grounding lug
ComplianceRoHS, UL/CSA/IEC safety certifications
WarrantyLimited 5‑year 

Warranty

Limited 5‑year 

Returns

We guarantee free replacements on all new/refurbished equipment in case of any defects.

  • Returns must be requested within 30 days of the original invoice date.
  • Merchandise must be unused and in original packaging; bulk-packed and refurbished items must have unbroken sealing tape.
  • A 25% restocking fee applies to non-defective merchandise returned by mistake.
  • Discontinued, close-out, and custom printed items are non-returnable unless defective.
  • Customer is responsible for return freight costs.

View full return policy

Customer Reviews of the Eaton PDUH20DV Tripp Lite Single Phase 100 240V Basic PDU Rack Mount

Based on 0 Reviews
5 Stars
0% (0)
4 Stars
0% (0)
3 Stars
0% (0)
2 Stars
0% (0)
1 Star
0% (0)

Filter Results

Do you own this product?

Write a Review

There are no reviews yet.

Write a Review

Your email address will not be published. Required fields are marked *

We Accept

  • PayPal
  • All Credit & Debit Cards
  • Purchase Orders
  • Check
  • Bank Transfer / ACH / Wire Transfer

To pay by PayPal or credit/debit card, simply check out and process payment online.

To pay by Purchase Order, Check, or Bank Transfer, please contact us:
Call: (469) 458-9636
Email: sales@dcsupplies.net

All packages are shipped same day if the order is placed before 3PM CST.

We use UPS/FedEx to ship packages, with different service levels offered by UPS/FedEx:

  • Overnight Shipping - 1 business day
  • Expedited Shipping - about 2-3 business days
  • Ground Shipping - about 3-5 business days

You can select the desired service level at checkout, and we will make sure the package is shipped per the selected service level.