APC AP8858 NetShelter Metered Rack PDU, 0U, 16A, 208/230V

Part No:AP8858 Write a Review

Condition:New

Brand:APC Electric

Weight:6.46 lbs

Product Type:Metered Rack PDU

APC AP8858 – Metered Rack PDU 0U 3.7kW

Overview :

The APC AP8858 is a metered rack power distribution unit designed to deliver monitored AC power distribution inside enterprise racks and data center cabinets. Infrastructure engineers deploy this PDU to distribute branch circuit power while providing real-time load visibility, enabling operators to track power usage and avoid circuit overload conditions that could disrupt critical systems. It is commonly installed in high-density racks supporting servers, storage arrays, and network equipment.

The unit supports single-phase 208 V or 230 V input power with a rated current of 16 A, delivering approximately 3.3 kW at 208 V or up to 3.7 kW at 230 V. Power is distributed through 20 AC outlets consisting of eighteen IEC C13 receptacles and two IEC C19 outlets, allowing mixed connection of standard IT equipment and higher-draw devices such as blade chassis or large network switches. The input connection uses an IEC 60320 C20 inlet, enabling integration with common data center power cabling.

The AP8858 is built in a vertical 0U form factor intended for installation along the side of standard 19-inch racks or cabinets without consuming rack units. This approach preserves valuable rack space for compute and networking hardware while still providing high-density outlet distribution. The PDU can operate in elevated rack temperatures up to 60 °C, supporting deployments in dense server environments where cabinet thermal conditions are higher than room ambient.

Operational visibility is provided through an integrated LCD metering display and remote monitoring capabilities. The unit measures and logs voltage, current, real power (kW), and energy consumption (kWh). Remote access is supported through network management interfaces including web access, SNMP, and command-line tools, enabling centralized monitoring within data center infrastructure management systems and energy tracking platforms.

In a practical deployment scenario, the AP8858 is typically installed in enterprise racks hosting virtualization clusters, storage nodes, or high-density switching environments. Administrators use the metering capability to monitor branch utilization, balance loads between redundant PDUs, and detect abnormal power consumption patterns before a breaker trip occurs.

This PDU should not be used when outlet-level switching or per-outlet metering is required. In environments requiring remote reboot control or outlet-level power measurement, switched or switched-metered PDUs are more appropriate.

Key Features :

• 0U vertical rack mounting for zero rack space consumption
• 18 × C13 and 2 × C19 outlets for mixed IT equipment loads
• PDU-level power metering for volts, amps, kW and kWh
• Network management via Web, SNMP and CLI interfaces
• IEC C20 inlet supporting 208 V or 230 V rack power feeds

BrandAPC Electric
SKUAP8858
ConditionNew
Dimensions1.732 × 2.205 × 35.512 in
Weight6.46 lbs
Part NumberAP8858
Product TypeMetered Rack PDU
Form Factor0U Vertical Rackmount
Input Voltage200 / 208 / 230 V AC
Input Frequency50 / 60 Hz
Rated Input Current16 A
Maximum Input Current20 A
Maximum Power3.3 kW (208 V) / 3.7 kW (230 V)
Input ConnectorIEC 60320 C20
Output Connectors18 × IEC C13, 2 × IEC C19
MonitoringCurrent, Voltage, Power, Energy
Operating Temperature5 °C to 45 °C
Operating Humidity5–95% non-condensing

Warranty

Products include the manufacturer warranty where applicable. Warranty coverage, term, and service options may vary by manufacturer and product condition.

Returns

We guarantee free replacements on all new/refurbished equipment in case of any defects.

  • Returns must be requested within 30 days of the original invoice date.
  • Merchandise must be unused and in original packaging; bulk-packed and refurbished items must have unbroken sealing tape.
  • A 25% restocking fee applies to non-defective merchandise returned by mistake.
  • Discontinued, close-out, and custom printed items are non-returnable unless defective.
  • Customer is responsible for return freight costs.

View full return policy

Customer Reviews of the APC AP8858 NetShelter Metered Rack PDU, 0U, 16A, 208/230V

Based on 0 Reviews
5 Stars
0% (0)
4 Stars
0% (0)
3 Stars
0% (0)
2 Stars
0% (0)
1 Star
0% (0)

Filter Results

Do you own this product?

Write a Review

There are no reviews yet.

Write a Review

Your email address will not be published. Required fields are marked *

We Accept

  • PayPal
  • All Credit & Debit Cards
  • Purchase Orders
  • Check
  • Bank Transfer / ACH / Wire Transfer

To pay by PayPal or credit/debit card, simply check out and process payment online.

To pay by Purchase Order, Check, or Bank Transfer, please contact us:
Call: (469) 458-9636
Email: sales@dcsupplies.net

All packages are shipped same day if the order is placed before 3PM CST.

We use UPS/FedEx to ship packages, with different service levels offered by UPS/FedEx:

  • Overnight Shipping - 1 business day
  • Expedited Shipping - about 2-3 business days
  • Ground Shipping - about 3-5 business days

You can select the desired service level at checkout, and we will make sure the package is shipped per the selected service level.